Sigma/ 2 (Basic Type)

The Sigma/ 2 diaphragm metering pump, together with pumps of type Sigma/ 1 and Sigma/ 3, represents an integrated product range. They cover the capacity range from 17 to 1,030 l/h, with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in ATEX areas.
Contact us to order

Industries Served

  • Metering of highly viscous substances such as polymers
  • Cyanide dosing in gold processing and treatment
  • Wastewater dosing in municipal sewerage treatment plants
  • Water treatment for boiler feed water in power stations
  • Chemical dosing in fertilizer manufacturing plants
  • Post process water treatment in reverse osmosis potable water plants
  • Highly robust metal inner housing for load stressed parts
  • Plastic housing to protect against corrosion
  • Capacity range 50 – 350 litres/hour, 12– 4 bar
  • Dosing accuracy is better than ± 2% in the stroke length range of 30 – 100%
  • Corrosion resistant plastic housing rated IP 65
  • Available in contact or analogue signal

NOTE: Product information should be used as a guide only and should not be used for pump selection. For further information, please contact Malcolm Thompson Pumps on 1800 439 607.

Part numberMax pump capacity at max back pressureMax stroke frequency (strokes/ min)Suction lift (mWG)Adm priming pressure suction sideConnector suction/ discharge sidePower supplyDelivery weight (kg)
(bar)(L/hr)(mL/ stroke)(bar)(DN)
S2BaHM16050PVT0010M000105011.47373151″ / 20mm1 ph. AC, 230 Volt, 50Hz, 0.18kW15
S2BaHM16090PVT0010M000109011.413273151″ / 20mm1 ph. AC, 230 Volt, 50Hz, 0.18kW15
S2BaHM16130PVT0010M0001013010.919873151″ / 20 mm1 ph. AC, 230 Volt, 50Hz, 0.18kW15
S2BaHM07120PVT0010M000712027.47351251 ½” / 25mm1 ph. AC, 230 Volt, 50Hz, 0.18kW16
S2BaHM07220PVT0010M000722027.713251251 ½” / 25mm1 ph. AC, 230 Volt, 50Hz, 0.18kW16
S2BaHM04350PVT0010M000435029.419851251 ½” / 25mm1 ph. AC, 230 Volt, 50Hz, 0.18kW16

Control

Part numberMax pump capacity at max back pressureMax stroke frequency (strokes/ min)Suction lift (mWG)Adm priming pressure suction sideConnector suction/ discharge sidePower supplyDelivery weight (kg)
(bar)(L/hr)(mL/ stroke)(bar)(DN)
S2CaHM16050PVT0010UC01000105011.47373151″ / 20mm1 ph. 100 – 230 Volt ± 10% 50Hz15
S2CaHM16090PVT0010UC01000109011.413273151″ / 20mm1 ph. 100 – 230 Volt ± 10% 50Hz15
S2CaHM16130PVT0010UC010001013010.919873151″ / 20 mm1 ph. 100 – 230 Volt ± 10% 50Hz15
S2CaHM07120PVT0010UC01000712027.47351251-½” / 25mm1 ph. 100 – 230 Volt ± 10% 50Hz16
S2CaHM07220PVT0010UC01000722027.713251251 ½” / 25mm1 ph. 100 – 230 Volt ± 10% 50Hz16
S2CaHM04350PVT0010UC01000435029.419851251 ½” / 25mm1 ph. 100 – 230 Volt ± 10% 50Hz16